Download Now

Cadence SPB OrCAD Hotfix SPB16.60.049 + Hotfix SPB17.00.002 - (Antonhyip)
Cadence SPB OrCAD Hotfix SPB16.60.049 + Hotfix SPB17.00.002 | 1.7GB

Cadence Design Systems Ltd., a world-renowned provider of EDA software, has released an hotfix 43 for Cadence SPB OrCAD 16.60, software a comprehensive package design of electronic circuits, analog and digital simulation, IC design of programmable logic and custom circuits, as well as the development and preparation for the production of printed circuit boards.
Cadence Design Systems, Inc., a leader in global electronic design innovation, launched the Cadence OrCAD 16.6 design solution with new features, enhanced customization capabilities, and 20 percent simulation performance improvements that provide customers a shorter, more predictable path to product creation.
This latest release offers numerous improvements to tool usability and performance, but at the heart of 16.6 are three key benefits: enhanced miniaturization capabilities, timing-aware physical implementation and verification for faster timing closure, and the industry's first electrical CAD team collaboration environment for PCB design using WeiRuan-->WeiRuan SharePoint technology.
DATE: 05-8-2015 HOTFIX VERSION: 049
1397185 PCB_LIBRARIAN VERIFICATION con2con is crashing but does not report ERROR message
1404854 ALLEGRO_EDITOR INTERFACES Allegro place DXF far from origin when importing
1404858 CONSTRAINT_MGR OTHER ERROR: Can not import electrical constraint data (pstcmdb.dat)
1411220 ALLEGRO_EDITOR INTERFACES Add option to include or exclude the SURFACE_INDEX_1 and SURFACE_2_BELOW_BOTTOM layers.
1411637 SCM SCHGEN Incorrect Ref Des in the Flattened Schematic
1411918 CONCEPT_HDL INTERFACE_DESIGN netgroups displayed even though no block placed
1413081 ALLEGRO_EDITOR OTHER DXF does not get correct pin offset value.
1413235 ALLEGRO_EDITOR INTERACTIV Find by Query with Via Structures: GUI freeze
1414685 ALLEGRO_EDITOR EDIT_ETCH Allegro crashes with remove tuning command
1415049 CONCEPT_HDL CONSTRAINT_MGR Cadence crash when "()" exist in diff pair names in ECLS
1415709 ALLEGRO_EDITOR REFRESH Updating a Mechanical Symbol causes Allegro to create a SAV file
1416217 ALLEGRO_EDITOR EXTRACT Problems with extracta
DATE: 05-01-2015 HOTFIX VERSION: 002
1315048 ALLEGRO_EDITOR INTERFACES IPC2581 translation inconsistency on negative layer
1362745 CONSTRAINT_MGR OTHER Allegro PCB Editor crashes on opening Constraint Manager with any design
1373412 ALLEGRO_EDITOR GRAPHICS SigXP Print Canvas: Via model seems to be filled by black Via box.
1376765 CONSTRAINT_MGR ANALYSIS Setup / Hold spreadsheet lists only one pin pair
1399646 ASI_SI OTHER Should be able to run mbs2brd with SI / PI base licenses
1400215 SIG_INTEGRITY REPORTS cross talk failure on certain nets in PCB SI 16.6
1400302 ALLEGRO_EDITOR MANUFACT Copper Thieving is working differently in SPB16.6 as compared to SPB16.5
1400755 ALLEGRO_EDITOR SHAPE Updating the shapes on the attached deisgn causes a short to a pad.
1400813 ALLEGRO_EDITOR SHAPE PCB Editor crashes when you delete islands from all the layers and save the board
1404174 SIP_LAYOUT OTHER Creating bounding shapes generates incorrect shapes and DRCs
1404184 ALLEGRO_EDITOR INTERFACES Step package mapping - Save is disabled for certain symbol
1406457 ALLEGRO_EDITOR SCRIPTS Unable to launch allegro.exe -orcad after update hotfix 046
1407123 ALLEGRO_EDITOR OTHER Lines with zero line width are not being printed in PDF format
1407483 ALLEGRO_EDITOR REFRESH The 'refresh symbol' command creates an unrouted connection in a fully routed design
1408072 SIP_LAYOUT OTHER Net assignment for a BGA component fails on running the File - Import - Netlist-in wizard command.
1410857 ALLEGRO_EDITOR DRC_CONSTR Diff Pair Uncoupled length DRC gives different results in SPB16.3, SPB16.5, and SPB16.6.
1413235 ALLEGRO_EDITOR INTERACTIV Find by Query with Via Structures: GUI freeze
Installing Hotfix SPB17.00 similar Hotfix SPB16.60.
It happens that after the upgrade, new problems. In any case, for the rollback, backup directory SPB_16.60 \ tools.
Do not make the top Hotfix patched SPB, will not operate.
It was the directory d: \ CAD \ SPB_16.60 \ installed the patched version.
Rename the d: \ CAD \ SPB_16.60 \ in d: \ CAD \ SPB_16.60 = \
Create an empty d: \ CAD \ SPB_16.60 \
Copy d: \ CAD \ SPB_16.60 = \ compnts.dat in d: \ CAD \ SPB_16.60 \
Making Hotfix.
Make a patch of SPB_16.60.000 (enough to make the d: \ CAD \ SPB_16.6 \ tools, the rest in the Hotfix has not been updated)
Transfer content for the d: \ CAD \ SPB_16.60 \ in d: \ CAD \ SPB_16.60 = \ with replacement
Rename the d: \ CAD \ SPB_16.60 = \ in d: \ CAD \ SPB_16.60
Date : 08-05-2015 (SPB16.60), 01-05-2015 (SPB17.00)
Version : SPB16.60 b049, SPB17.00 b002
Developer : Cadence
Website Developer :
Bit : x32 SPB16.60, x64 SPB17.00
Compatible with Win7 : Yes
Language : English

Buy Premium From My Download Links To Get Resumable Support, Max Speed & Support Me

Download from nitroflare_com

Download from uploaded_net

Download from rapidgator_net

Download from uploadable_ch

All above links are interchangable. No password

Cadence SPB OrCAD Hotfix SPB16.60.049 + Hotfix SPB17.00.002
Direct Download

Tags: Cadence, Hotfix, Hotfix, Antonhyip

Add Comments:
Enter Code: *